What was found
FOUND 'L' ANGLE CRACKED AT STA 663 R/H SIDE A/C BAY FROM FASTENER HOLE. 5TH FASTENER FROM O/B BULKHEAD DIVIDER.<[01] INSPRJCT: WORK ACCOMPLISHED IN STEPS 1; 2 AND 3 ARE MISSING THE WORK REFERENCE AS REQUIRED PER MPM 51.3.1. WORK ACCOMPLISHED IN STEPS 1; 2 AND 3 REQUIRE INSPECTION BUYBACK PER MPM CHAPTER 10. MATCH DRILLED REPLACEMENT ANGLE PER SRM 51-40-02. MATCHED DRILLED REPLACEMENT ANGLE PER SRM 51-40-02. OK TO INSTALL REPLACEMENT ANGLE. OK TO CAP SEAL FASTENERS. REMOVED AND REPLACED L ANGLE AT BS 663 FROM APPROX RBL 5 TO RBL 65 IAW SRM 51-40-02 AND AS REQUIRED PER SRM 51-10-10-2R-5. R & R L ANGLE AT BS 663 FROM APPROX RBL 5 TO RBL 65 IAW SRM 51-40-02 AND AS REQUIRED PER SRM 51-10-10-2R-5.