What was found
DOT A24-11 AFT PIT INTERCOSTAL FOR FORWARD SHIELD IS CORRODED ON UPPER SURFACE BETWEEN STATIONS 767 THROUGH 787 RBL 24 WL 156.<[01] EVALUATED AREA; VERIFIED LIMITS ORIGINAL THICKNEES:0.050'; MATERIAL LOSS: 50%; WITH THE MAX. ALLOWABLE DAMAGE 10% (0.005); THEREFORE IS OUT OF THE LIMITS I.A.W. SRM 53-60-15-1A-1 REMOVED AND INSTALLED NEW AFT PIT INTERCOSTAL FOR FWD SHIELD STA 767 - 787 RBL 24 I/A/W SRM 51-40-02-0G-0 AND BOEING DWG 146A0081 REV A;[02] C/W<BR>AUDIT C/W