What was found
CRACK INDICATION FOUND ON RT HORIZONTAL STABILIZER LOWER SKIN PANEL. LOCATED AT STAB STA 193.9 RIB AND 16 INCH. FROM FRONT SPAR. INBOARD SIDE OF RIB. CRACK LENGTH = 0.960 INCH. APPROX. 2024-766340<[01] EQUIPMENT P/N PHASEC 3D; S/N 800YBRK; DUE DATE 16-JUL-25 WAS USED ON STEP 5 AND STEP 6;[02] PERFORMED REPAIR CAT B LOCATED ON RT HORIZONTAL STABILIZER LOWER SKIN PANEL. BTW STAB STA 184.70 RIB TO STAB STA 203.10 RIB AND 16 INCH. FROM FRONT SPAR IAW B737-700 SRM 55-10-01-2R-11<BR>SEE INDIVIDUAL SIGN OFF BELOW;[03] PERFORMED REPAIR CAT B LOCATED ON RT HORIZONTAL STABILIZER LOWER SKIN PANEL. BTW STAB STA 184.70 RIB TO STAB STA 203.10 RIB AND 16 INCH. FROM FRONT SPAR IAW B737-700 SRM 55-10-01-2R-11<BR>RII ITEM<BR>SEE INDIVIDUAL SIGN OFF BELOW