What was found
CRACK ANGLE SLAT 8 LOCATED ON AUXILIARY TRACK LOWER AREA INTERNAL CAVITY AT RT WING 2024-758727<[01] REPLACED ANGLE SLAT 8 LOCATED ON AUXILIARY TRACK LOWER AREA INTERNAL CAVITY AT RT WING WING IAW B737-700 SRM 51-40-02; SRM 51-10-02 ITEM 9 AND DRAWING 114A5030 SHEET 14 REV.B<BR>MEASURE OF CRACK IS: 2.00' TOOL USED CALIPER P/N:500-197-30 S/N:B23412298 DUE DATE:10NOV25;[02] CORRECTED STEP 1<BR>REPLACED ANGLE SLAT 8 LOCATED ON AUXILIARY TRACK LOWER AREA INTERNAL CAVITY AT RT WING WING IAW B737-700 SRM 51-40-02; SRM 51-10-02 ITEM 9 AND DRAWING 114A5010 SHEET 14 REV.C<BR>MEASURE OF CRACK IS: 2.00' TOOL USED CALIPER P/N:500-197-30 S/N:B23412298 DUE DATE:10NOV25;[03] CERTIFIED WORK PERFORMED.