What was found
L/H VAPOR BARRIER ATTACH ANGLE STA 663 HAS CRACK ON VERTICAL LEG AT LBL 35< CUT AND REMOVED DAMAGED L/H VAPOR BARRIER ATTACH ANGLE STA 663 FROM LBL 31 TO LBL 65 PER SRM 57-10-10-2R-5 REPAIR 5.;[04] FORMED SPLICE ANGLE FROM .071? THICK 2024-T3 CLAD SHEET PER SRM 57-10-10-2R-5. PHOTO ATTACHED FABRICATED; LOCATED; AND DRILLED L/H VAPOR BARRIER ATTACH ANGLE STA 663 REPAIR SPLICE PER SRM 57-10-10-2R-5 AND EA 25-157-00119. TREATED AND PRIMED REPAIR SPLICE PER SRM 57-10-10-2R-5 AND EA 25-157-00119] INSTALLED REPAIR SPLICE RIVETS THROUGH VERTICAL LEG AND 5 ADDITIONAL -5 RIVETS THROUGH THE VERTICAL LEG OF REPAIR ANGLE PER SRM 57-10-10-2R-5 AND EA 25-157-00119 AND EA M-24-157-02340. INSTALLED NEW REPAIR ANGLE AND SPLICE PER SRM 57-10-10-2R-5 AND EA 25-157-00119 AND EA M-24-157-02340. SIGNOFF FOR STEPS 14 AND 20 ONLY.;[22] RII. VERIFIED. INSTALLED NEW REPAIR ANGLE AND SPLICE PER SRM 57-10-10-2R-5 AND EA 25-157-00119 AND EA M-24-157-02340. SIGNOFF FOR STEPS 14 AND 20 ONLY.;[23] ACCOMPLISHED REPAIR OF L/H VAPOR BARRIER ATTACH ANGLE STA 663 AT LBL 35 PER SRM 57-10-10-2R-5; EA 25-157-00119; AND EA M-24-157-02340.;[24] RII: INSPECTED WORK PERFORMED. SEE STEPS AND C/A?S FOR ALL WORK PERFORMED. ACCOMPLISHED REPAIR OF L/H VAPOR BARRIER ATTACH ANGLE STA 663 AT LBL 35 PER SRM 57-10-10-2R-5; EA 25-157-00119; AND EA M-24-157-02340.