What was found
CUSTOMER REQUEST AAI INSPECTION MAIN CABIN; FLOOR STRUCTURE SUPPORT HAS CRACK AT STA 540; BL 0 TO LBL 24.75 2024-758947<[01]. REPLACED BREAK ASSY PANEL AND FASTENERS AT STA 540; BL 0 TO LBL 24.75 IAW B737-700 SRM 51-40-02 SRM 51-10-02 ITEM 9 AND DWG 143A0060 SHEET 46 REV- SEE INDIVIDUAL SIGN OFFS BELOW; [02] BATCH NO 563580 ENTER BY ERROR. THE CORRECT BATCH NO IS 449126.; [03] CERTIFIED WORK PERFORMED. SEE INDIVIDUAL SIGN OFF BELOW.