What was found
CRACK ON WEB INTERCOSTAL LOCATED BTW BS 344 TO BS 360 LBL 11 WL 208.1 AT FWD GALLEY AREA 2024-779258<[01]. REPLACED INTERCOSTAL WEB LOC. FLOOR STRUCTURE BTW BS 344 TO BS 360 LBL 11 WL 208.1 AT FWD GALLEY AREA IAW B737-800 SRM 51-40-02-0G-0; SRM SRM 51-10-02 ITEM 9 AND DWG 141A5400 SHEET 46 REV A. SEE INDIVIDUAL SIGN OFFS BELOW.; [02] REPLACED INTERCOSTAL WEB LOC. FLOOR STRUCTURE BTW BS 344 TO BS 360 LBL 11 WL 208.1 AT FWD GALLEY AREA IAW B737-800 SRM 51-40-02-0G-0; SRM SRM 51-10-02 ITEM 9 AND DWG 141A5400 SHEET 46 REV A. SEE INDIVIDUAL SIGN OFFS BELOW. RII CERTIFIED.