What was found
CRACK ON SUPPORT ANGLE LOCATED BTW BS 294.5 TO BS 303.9 RBL 52 WL 208.1 AT FWD GALLEY AREA 2024-779260 <[01]. REPLACED SUPPORT ANGLE AND FASTENERS LOCATED BTW BS 294.5 TO BS 303.9 RBL 52 WL 208.1 AT FWD GALLEY AREA I.A.W. B7373-800 SRM 51-40-02;SRM 51-10-02 PARAGRAPH 9AND DWG 141A8310 SHEET 33 REV. -; [02] CORRECTED STEP 1. REPLACED SUPPORT ANGLE AND FASTENERS LOCATED BTW BS 294.5 TO BS 303.9 RBL 52 WL 208.1 AT FWD GALLEY AREA I.A.W. B7373-800 SRM 51-40-02;SRM 51-10-02 PARAGRAPH 9AND DWG 141A8310 SHEET 33 REV.- .SEE INDIVIDUAL SIGN OFFS BELOW.; [03] REPLACED SUPPORT ANGLE AND FASTENERS LOCATED BTW BS 294.5 TO BS 303.9 RBL 52 WL 208.1 AT FWD GALLEY AREA I.A.W. B7373-800 SRM 51-40-02;SRM 51-10-02 PARAGRAPH 9 AND DWG 141A8310 SHEET 33 REV.- .SEE INDIVIDUAL SIGN OFFS BELOW.