What was found
FED CUTOUT SURROUND STRUCTURE; UPPER CHORD WEB BS 312 BETWEEN S6L AND S7L HAS A CRACK (MARKED).<[01] AFTER NDI EVALUATION AT DISCREPANCY AREA; NO CRACK NOTED IAW 737 NDTM PART 6; 51-00-00 PROCEDURE 23.<BR>TOOL USED:<BR>ID ATS1465<BR>CAL. DUE 07/2025.;[02] UPPER CHORD WEB AT FED REINSPECTED AND CRACK CONFIRMED AT LOCATION STA-312 STR-5L TO 6L; REPAIR OR REPLACEMENT REQUIRED.;[03] REPAIRED DISCREPANCY AREA PER REF EA M-22-153-01244 ON CARD NBR TTG8Q00YCV3Z;[04] CORRECTIVE ACTION COMPLETED.