What was found
CRACK INDICATION ON STUB FRAME LOCATED ON BS 296.5 BTW S-8R TO S-9R AT FWD GALLEY DOOR AREA CRACK LENGTH 0.436 IN. APROX.AT PASSENGER CABIN 2025-91761<[01] REPLACED STUB FRAME AND FASTENERS LOCATED ON BS 296.5 IAW B737-700 SRM 51-40-02 ABD DRAWING 141A8370 SHEET 10 REV. D.SEE INDIVIDUAL STEPS SIGNOFF BELOW;[02] RII ITEM <BR>REPLACED STUB FRAME AND FASTENERS LOCATED ON BS 296.5 IAW B737-700 SRM 51-40-02 ABD DRAWING 141A8370 SHEET 10 REV. D.SEE INDIVIDUAL STEPS SIGNOFF BELOW