What was found
FWD CARGO FLOOR PANEL 120CF HAS CORROSION AT FASTENER HOLES<[01] UPON FURTHER INVESTIGATION FOUND THAT CORROSION WAS 30 INCHES IN LENGTH WITH A MAX ALLOWED LENGTH OF 3 INCHES FOUND TO BE OUT OF LIMITS IAW SRM 53-00-53-1A-1; RECEIVED REPLACEMENT MATERIAL PN 2024-T3-.071 A TAG A276640 AND VERIFIED TO BE CORRECT REPLACEMENT MATERIAL IAW SRM 53-60-53-0I-1; FABRICATED NEW PANEL FOR 120CF IAW AMM 25-52-01-201-801; TREATED NEW PANEL IAW AMM 51-21-41-701 AND PRIMED NEW PANEL IAW AMM 51-21-72-370-804;[02] C/W<BR>AUDIT C/W