What was found
CABIN FWD WET AREA R1 CREASE BEAM CRRODED AT STA 312+15' LBL 60 WL 208<[01] REMOVED DAMAGE FROM CABIN FWD WET AREA R1 CREASE BEAM CORRODED AT STA 312+15' LBL 60 WL 208; FOUND IT OUT OF LIMITS ; ORIG T . ADJACENT TO BLEND .085'; LOSS .017'; REMOVED DAMAGED PART ;LOCATED; DRILLED;INSTALLED NEW R1 DOOR CREASE BEAM P/ N 6540004-134;A TAG# WN11061;APPLIED CIC ON NEW PART. IAW SRM 51-10-02; SRM 51-40-05; DWG # 141A8310; REV B; DWG # 141A8310; REV:-A; AMM 51-21-91.