What was found
AFT CARGO COMPARTMENT RH FWD SHIELD BOTTOM ATTACHING ANGLE CORRODED AROUND NUTPLATES STA 767+6' RBL 21 WL 156<[01] REMOVED CORROSION AND VERIFIED WITH 10X ALL REMOVED IAW SRM 51-10-02-0G-0<BR>UT IAW B737 NDT PART 4; 51-00-00 PROC 2. ADJACENT TO BLEND .050'; LOSS .009'; REMAINING .041'. TOOL#40084; DUE 06AUG25<BR>ORIGINAL MATERIAL THICKNESS .050'; REMAINING MATERIAL .041'; .009' LOSS OF MATERIAL; .005' MATERIAL LOSS LIMIT; FOUND TO EXCEED MAXIMUM ALLOWABLE DAMAGE LIMITS IAW SRM 53-60-15-1A-1.<BR>REMOVED; LOCATED; DRILLED AND INSTALLED NEW ANGLE ON AFT CARGO COMPARTMENT RH FWD SHIELD BOTTOM STA 767+6' RBL 21 WL 156 IAW SRM 51-40-05-0G-0 I.A.W. SRM 51-40-02-0G-0 AND DWG 146A8123 REV:-;[02] WORK CARD C/W<BR><BR>AUDIT C/W