What was found
DOT L7-005: AFT CARGO FLOOR PANEL 140BF HAS CORROSION AT FASTENER HOLES<[01] EVALUATED CORROSION ON FLOOR PANEL 140BF WITH THE TOTAL ACCUMULATED DAMAGE LENGTH IS 32' WERE IS A MAXIMUM OF 20' ON ALLOWABLE DAMAGE; THEREFORE IS OUT OF LIMITS; MECHANICALLY MEASURED I.A.W SRM 53-00-53-1A-1.<BR>FABRICATED NEW FLOOR PANEL 140BF I.A.W SRM 53-00-53-1A-1 AND APPLIED ALODINE AND PRIMER I.A.W AMM 51-21-41-701 AND AMM 51-21-72-370-804;[02] VERIFIED STEP 1<BR>AUDIT CW