What was found
MAIN CABIN FWD WET AREA; FLOOR SUPPORT CORRODED BETWEEN BS 328 AND BS 344 APPROX. LBL-45. <[01] MAIN CABIN FWD WET AREA; FLOOR SUPPORT CORRODED BETWEEN BS 328 AND BS 344 APPROX. LBL-45. EVALUATED DAMAGE AND FOUND OUT OF LIMITS IAW B737-800 SRM 53-10-51-1A-1 AND BOEING DWG 141A5770 REV:A; DAMAGE DEPTH: 0.044' ORIGINAL THICKNESS: 0.080'; REMOVED FLOOR SUPPORT IAW B737-800 SRM 51-40-02; RECEIVED NEW PART P/N: 141A5770U3 INTERCOSTAL; PO: 0 IAW B737-800 IPC 53-42-11-44; LOCATED & DRILLED IAW B737-800 SRM 51-40-05 & BAC DWG 141A5730 REV. A. AND INSTALLED IAW B737-800 SRM 51-40-02 & BAC DWG 141A5730 REV. A; [04] VERIFIED MAIN CABIN FWD WET AREA; FLOOR SUPPORT CORRODED BETWEEN BS 328 AND BS 344 APPROX. LBL-45. EVALU