What was found
(CUSTOMER REQUEST) MAIN CABIN; FLOOR STRUCTURE SUPPORT HAS CRACK AT STA 540; BL 0 TO RBL 24.75. 2025-94369<[01] REPLACED MAIN CABIN FLOOR STRUCTURE SUPPORT LOCATED AT STA540 BL 0 TO RBL 24.75 IAW B737-700 SRM 51-10-02 ITEM 9 AND DWG# 143A0060 SHEET 46 REV. - SEE INDIVIDUAL SIGN OFF BELOW;[02] REPLACED MAIN CABIN FLOOR STRUCTURE SUPPORT LOCATED AT STA540 BL 0 TO RBL 24.75 IAW B737-700 SRM 51-10-02 ITEM 9 AND DWG# 143A0060 SHEET 46 REV. - SEE INDIVIDUAL SIGN OFF BELOW