As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
R/H OVERWING INTERIOR EXIT LIGHT LOWER AND UPPER INOP<[01] REPLACED FUSE 1 TO POWER SUPPLY M1669 PER AMM 33-51-06-960-804 AND WM 33-51-21. GOOD OPERATIONAL TEST.;[02] PERFORMED FIM TASK 33-50 TASK 801 STEP J; 3. FOUND BAD FUSE. REPLACED FUSE 1 TO POWER SUPPLY M1669 PER AMM 33-51-06-960-804 AND WM 33-51-21. GOOD OPERATIONAL TEST.<BR><BR>MULTIMETER<BR>ID: ATS1508<BR>DUE: 09/2025;[03] VERIFIED CORRECTIVE ACTION