What was found
CORROSION ON STRAP AT MID CABIN BS707 RBL63 WL203. MARKED <[01] REJECTED; AMT REQUEST FOR NDI TO VERIFY REMAINING THICKNESS OF PART. AMT DID NOT PROVIDE STRUCTURE ID/DRAWING AS REQUIRED IAW 737 NDTM PART 4; 51-00-00; PROC 2 STEP 4. C.; [02] REMOVED CORROSION ON STRAP AT MID CABIN BS707 RBL63 WL203. BLEND WAS 1'X.5'. BLEND IS OUT OF LIMITS DUE TO NO LIMITS IN SRM. TREATED AND PRIMED BLENDED AREAS IAW SOPM 20-41-02. UT INSPECTED BLENDED AREA IAW 737 NDTM PART 4; 51-00-00 PROCEDURE 2. SEE ATTACHED FILE. EQUIP USED: -EPOCH 650 ID: ATS2031 CAL DUE: 07/25; [03] REMOVED CORROSION ON STRAP AT MID CABIN BS707 RBL63 WL203. BLEND WAS 1'X.5'. BLEND IS OUT OF LIMITS DUE TO NO LIMITS IN SRM. TREATED AND PRIMED BLENDED AREAS IAW SOPM 20-41-02. UT INSPECTED BLENDED AREA IAW 737 NDTM PART 4; 51-00-00 PROCEDURE 2. SEE ATTACHED FILE 'REFER TO FAULT TTG8Q00YQ32J WHERE 25-153-00427 WAS ADDED AS A SUBTASK; [04] VERIFIED COMPLETION CORRECTIVE ACTION 3 AND MEASUREMENT TABLE.