What was found
CRACK ON STRINGER 25L LOCATED BTW BS520 TO BS540 AT FWD CARGO COMPARTMENT 2025-136937<[01] ON STEP 2: TOOL USED ULTRASONIC EQUIPMENT PN: 45MG; SN: 221859911; DUE DATE: 19 DEC 25;[02] TOOLS USED: TEMPERATURE CONTROLLER P/N: P3015GOES00000; S/N: 142811020; DUE DATE: 29-JAN-26; TEMPERATURE CONTROLLER P/N: P3015GOES00000; S/N: 142811019; DUE DATE: 29-JAN-26.;[03] TOOL USED: EDDY CURRENT EQUIPMENT P/N NORTEC 600D S/N 90023010 DUE DATE: 05-AUG-25.;[04] REPAIRED STRINGER 25L LOCATED BS500D MORE 10 INCH TO BS540 IAW B737-700 SRM 53-00-03-2R REPAIR 1 SEE INDIVIDUAL SIGN OFF BELOW;[05] CORRECTED STEP 4.REPAIRED STRINGER 25L LOCATED BS500D MORE 10 INCH TO BS540 IAW B737-700 SRM 53-00-03-2R-1 REPAIR 1 SEE INDIVIDUAL SIGN OFF BELOW.;[06] TASK COMPLETED ; RII <BR>SEE INDIVIDUAL SIGN OFF BELOW.