What was found
CRACK WEB - INTERCOSTAL FLOOR STRUCTURE LOCATED BTW STA 328 TO STA 344 AND LBL 47 FWD GALLEY AND LAV 2025-167671<[01] REPLACED WEB INTERCOSTAL FLOOR STRUCTURE LOCATED BTW STA 328 TO STA 344 AND LBL 47 FWD GALLEY AND LAV IAW B737-700 SRM 51-40-02 AND DWG 141A5400 SHEET 44 REV - SEE INDIVIDUAL SIGN OFF BELOW.;[02] REPLACED WEB INTERCOSTAL FLOOR STRUCTURE LOCATED BTW STA 328 TO STA 344 AND LBL 47 FWD GALLEY AND LAV IAW B737-700 SRM 51-40-02 AND DWG 141A5400 SHEET 44 REV -<BR>SEE INDIVIDUAL SIGN OFF BELOW.