What was found
CRACK STUB FRAME LOCATED STA 294.5 AT LEVEL STR 17R AT FWD GALLEY AREA 2025-167697<[01] REPLACED STUB FRAME; SERATE PLATE (2 EA) AND LOWER REVEAL CORNER LOCATED BS 294.5 TO BS 296 BETWEEN STR14 R TO STR 17 R FWD GALLEY AREA B737-700 SRM 51-40-02 AND DWG 141A8370 SHEET 16 REV - DWG 141A8370 SHEET 10 REV D SEE INDIVIDUAL SIGN OFF BELOW.;[02] CORRECTED STEP 1 <BR>REPLACED STUB FRAME; SERATE PLATE (2 EA) AND LOWER REVEAL CORNER LOCATED BS 294.5 TO BS 296 BETWEEN STR14 R TO STR 17 R FWD GALLEY AREA B737-700 SRM 51-40-02;DWG 141A8370 SHEET 16 REV - ;DWG 141A8370 SHEET 10 REV D AND DWG 141A8430 SHEET 4 REV B.;[03] CORRECTED STEP 1 AND 2. <BR>REPLACED STUB FRAME LOCATED BS 294.5 TO BS 296 BETWEEN STR14 R TO STR 17 R FWD GALLEY AREA B737-700 SRM 51-10-2-0G-0 PARRG 9 AND SRM 51-40-02;DWG 141A8370 SHEET 16 REV - ;DWG 141A8370 SHEET 9 REV D AND DWG 141A8430 SHEET 4 REV B.;[04] TASK COMPLETED <BR>CERTIFIED RII