What was found
CRACK INDICATION ON STUB FRAME LOCATED ON BS 296.5 BTW S-8R TO S-9R AT FWD GALLEY DOOR AREA CRACK LENGTH 0.375 IN. APROX.AT PASSENGER CABIN 2025-203649<[01] REPLACED STUB FRAME AND FASTENERS LOC. BETWEEN STR7R TO STR11R AT FWD GALLEY AREA IAW B737-700 SRM 51-10-02 ITEM 9 AND DWG DWG 141A8370 SHEET 9; REV. ; AND DWG 141A8370 SHEET 10; REV. .<BR>SEE INDIVIDUAL SIGN OFFS BELOW;[02] CORRECTED ITEM 1 <BR>REPLACED STUB FRAME AND FASTENERS LOC. BS296.5 BETWEEN STR7R TO STR11R AT FWD GALLEY AREA IAW B737-700 SRM 51-10-02 ITEM 9 AND DWG DWG 141A8370 SHEET 9; REV. ; AND DWG 141A8370 SHEET 10; REV. .<BR>SEE INDIVIDUAL SIGN OFFS BELOW;[03] REPLACED STUB FRAME AND FASTENERS LOC. BS296.5 BETWEEN STR7R TO STR11R AT FWD GALLEY AREA IAW B737-700 SRM 51-10-02 ITEM 9 AND DWG DWG 141A8370 SHEET 9; REV. ; AND DWG 141A8370 SHEET 10; REV. .<BR>SEE INDIVIDUAL SIGN OFFS BELOW. CERTIFIED AS RII.