What was found
MAIN CABIN; FLOOR STRUCTURE SUPPORT HAS CRACK AT STA 540; BL 0 TO RBL 24.75.<[01] REMOVED AND REPLACED MAIN CABIN; FLOOR STRUCTURE SUPPORT<BR>IAW SRM 51-40-02 & DWG 143A0060; BS540; BL0 - RBL 24;[02] REMOVED AND REPLACED MAIN CABIN FLOOR STRUCTURE SUPPORT AT STA 540; BL 0 TO RBL 24-75 PER SRM 51-40-02. REMOVED AND REINSTALLED FLOOR PANEL 231UF PER SRM 51-40-02 AND AMM 53-21-00-400-801. USED 35 INLB SCREW GUN ID IS000955 DATE 10/2024 CAL DUE DATE 10/2025.;[03] CORRECTIVE ACTION ITEM 2 VERIFIED; CARD COMPLETE.