What was found
L/H MAIN FLAP T/E WEDGE HAS 2 SMALL AREAS OF DELAMINATION<[01] REMOVED DAMAGE TO AREA PER SRM 57-53-01-2R-7.;[02] 02 - INSPECTED PER [SRM 57-53-01-2R-7-B00269 (REPAIR 7 - INBOARD MAIN FLAP TRAILING EDGE WEDGE - PERMANENT)];[03] PART TOOLING UPDATE.;[04] REPAIRED PER SRM 57-53-01-2R-7.;[05] C/W INSPECTION OF CORRECTIVE ACTION STEP #4 AND C/W ULTRASONIC BOND INSPECTION PER NDT PART 1 51-04-00 NO DEFECTS NOTED.;[06] RESTORED FINISH PER SRM 57-53-01-2R-7 AND AMM 51-21-99.;[07] C/W RII INSPECTION;[08] C/W INSPECTION