What was found
CRACK ANGLE - SUPPORT LOCATED BTW STA 380 TO STA 400 AND LBL 13 AT FWD GALLEY AREA 2025-202773<1. REPLACED ANGLE - SUPPORT LOCATED BTW STA 380 TO STA 400 AND LBL 13 AT FWD GALLEY AREA IAW B737-700 SRM 51-10-02-0G, SRM 51-40-02 AND DWG 143A5400 SHEET 38 REV A . SEE INDIVIDUAL SIGN OFF BELOW. 2. CERTIFIED CORRECTIVE ACTION 1, COMPLETED