What was found
AAI MAIN CABIN; FLOOR STRUCTURE SUPPORT HAS CRACK AT STA 540; BL 0 TO LBL 24.75 2025-232405<[01] REPLACED FLOOR STRUCTURE BRACKET LOCATED STA 540; BL 0 TO LBL 24.75 IAW B737-700 SRM 51-40-02 DWG 143A0060 SHEET 46 REV- SEE INDIVIDUAL SIGN OFFS BELOW.;[02] CORRECTED STEP 1. REPLACED FLOOR STRUCTURE SUPPORT LOCATED STA 540; BL 0 TO LBL 24.75 IAW B737-700 SRM 51-40-02 DWG 143A0060 SHEET 46 REV- SEE INDIVIDUAL SIGN OFFS BELOW.;[03] REPLACED FLOOR STRUCTURE SUPPORT LOCATED STA 540; BL 0 TO LBL 24.75 IAW B737-700 SRM 51-40-02 DWG 143A0060 SHEET 46 REV- SEE INDIVIDUAL SIGN OFFS BELOW.