What was found
CRACK INDICATION ON STUB FRAME LOCATED BTW BS 294.5 TO BS 296 AND S-8R TO S-9R AT FWD GALLEY DOOR AREA(1EA). CRACK LENGTH APPROX 0.875 INCH AT PASSENGER CABIN 2025-232168<[01] REPLACED STUB FRAME LOCATED BTW BS 294.5 TO BS 296 AND BTW STR 6R TO STR 10R AT FWD SERVICE DOOR AT PASSENGER CABIN IAW B737-700 SRM 51-40-02; DWG: 141A8370 SHEET: 10 REV:D ; DWG: 141A8380 REV: 22 REV: - AND DWG: 141A3330 SHEET: 4 REV: -. SEE INDIVIDUAL SIGN OFF BELOW.;[02] REPLACED STUB FRAME LOCATED BTW BS 294.5 TO BS 296 AND BTW STR 6R TO STR 10R AT FWD SERVICE DOOR AT PASSENGER CABIN IAW B737-700 SRM 51-40-02; DWG: 141A8370 SHEET: 10 REV:D ; DWG: 141A8380 REV: 22 REV: - AND DWG: 141A3330 SHEET: 4 REV: -. SEE INDIVIDUAL SIGN OFF BELOW.<BR>RII CERTIFIED