What was found
CRACK WEB - INTERCOSTAL FLOOR STRUCTURE LOCATED STA312 TO STA328 AND LBL45 FWD GALLEY AND LAV 2025-250259 <[01]. REPLACED NEW WEB - INTERCOSTAL FLOOR STRUCTURE AND FASTENERS LOCATED STA312 TO STA328 AND LBL45 FWD GALLEY AND LAV IAW B737-700 SRM 51-10-02 AND DWG 141A5400 SHEET 26 REV. SEE INDIVIDUAL SIGN-OFFS BELOW.; [02] REPLACED NEW WEB - INTERCOSTAL FLOOR STRUCTURE AND FASTENERS LOCATED STA312 TO STA328 AND LBL45 FWD GALLEY AND LAV IAW B737-700 SRM 51-10-02 AND DWG 141A5400 SHEET 26 REV. SEE INDIVIDUAL SIGN-OFFS BELOW.