What was found
AFTER REMOVE SEAL DEPRESSOR CRACK INDICATION FOUND ON STUB FRAME LOCATED ON BS 296.5 BTW STR 8 TO S-9R AT FWD GALLEY DOOR AREA. CRACK LENGTH : 0.395 INCHES APPROX AT PASSENGER CABIN. 2025-250429<[01] REPLACED STUB FRAME AND FASTENERS LOCATED ON BS 294.5 AT FWD GALLEY DOOR AREA I.A.W B737-700 SRM 51-40-02-0G-0 AND DWG# 141A8370; SHEET 9; REV.D. SEE INDIVIDUAL SIGN OF BELOW.;[02] REPLACED STUB FRAME AND FASTENERS LOCATED ON BS 294.5 AT FWD GALLEY DOOR AREA I.A.W B737-700 SRM 51-40-02-0G-0 AND DWG# 141A8370; SHEET 9; REV.D. SEE INDIVIDUAL SIGN OF BELOW. RII.