What was found
BROKEN EMERGENCY EXIT LIGHT ASSY LAVATORY B AT AFT GALLEY AREA (1 EA) 2025-274445 <[01]. REPLACED HOSE AIR DUCK ON LAVATORY A AT FWD GALLEY AREA IAW B737-700 AMM 33-51-01-960-802 STEP 3.C.(5)(D) THRU 3.C.(7);[02] CORRECTED STEP 1: REPLACED HOSE AIR DUCK ON LAVATORY A AT FWD GALLEY AREA IAW B737-700 AMM 33-51-01-960-802 STEP 3.C.(5)(D) THRU 3.C.(7). TEST IS OK; [03] REPLACED EMERGENCY LENS ON GALLEY 4 AT AFT GALLEY AREA (1 EA) IAW B737-700 AMM 33-51-01-960-802 STEP 3.C.(5)(D)(7)(10). TEST IS OK.