What was found
CRACK STRINGER 23R LOCATED STA 540 FWD CARGO COMPARTMENT 2025-291241<[01] TOOL USED ULTRASONIC THICKNESS GAGE P/N : 45MG ; S/N : 1300 66401 ; DUE DATE: 21/OCT/25; [02] TOOL USED: EDDY CURRENT FLAW DETECTOR; P/N: NORTEC 500 D; S/N: N500X12101V022235; DUE DATE: 07-OCT-25.; [03] PERFORMED PERMANENT REPAIR ON STRINGER 23R LOCATED BTW BS500D TO BS540 AT FWD CARGO COMPARTMENT IAW B737-700 SRM 53-00-03-2R-1 REPAIR 1. SEE INDIVIDUAL SIGN OFFS BELOW.; [04] CERTIFIED AS ITEM RII PERFORMED PERMANENT REPAIR ON STRINGER 23R LOCATED BTW BS500D TO BS540 AT FWD CARGO COMPARTMENT IAW B737-700 SRM 53-00-03-2R-1 REPAIR 1. SEE INDIVIDUAL SIGN OFFS BELOW.