What was found
(CUSTOMER REQUEST) CRACK ON VAPOR BARRIER LOCATED AT BS 663.75 BETWEEN RBL 40 TO RBL 55 RH SIDE WHEEL WELL COMPARTMENT 2025-290824 <[01]. TOOL USED: CALIPER: P/N: 500-197-30; S/N: A23304055; DUE DATE: 10-NOV-25; [02] TOOL USED: SCALE P/N 91847 S/N AE-409317 DUE DATE: 29-JUN-25.; [03] TOOL USED: HOT BONDER P/N: HCS9000B-AV; S/N: 18185781; DUE DATE: 22-FEB-26.; [04] TOOL USED: SCALE P/N 91847 S/N AE-409319 DUE DATE: 29-SEP-25; [05] TOOL USED: ULTRASONIC FLAW DETECTOR; P/N: EPOCH 650; S/N: 201036102; DUE DATE: 25-OCT-25.; [06] REPAIRED VAPOR BARRIER LOCATED AT BS 663.75 BETWEEN RBL 40 TO RBL 55 RH SIDE WHEEL WELL COMPARTMENT IAW B737-700 SRM 51-70-04-2R-10 REPAIR 10. SEE INDIVIDUAL SIGN OFFS BELOW; [07] CORRECTIVE ACTION 6 WAS MODIFIED ADDED TOOL USED OF STEP 5: HOT BONDER P/N: HCS9000B; S/N: 18196119; DUE DATE: 13 JUN 25.<BR><BR>REPAIRED VAPOR BARRIER LOCATED AT BS 663.75 BETWEEN RBL 40 TO RBL 55 RH SIDE WHEEL WELL COMPARTMENT IAW B737-700 SRM 51-70-04-2R-10 REPAIR 10. SEE INDIVIDUAL SIGN OFFS BELOW; [08] CERTIFIED AS RII CORRECTIVE ACTION 7 CORRECTIVE ACTION 6 WAS MODIFIED ADDED TOOL USED OF STEP 5: HOT BONDER P/N: HCS9000B; S/N: 18196119; DUE DATE: 13 JUN 25. REPAIRED VAPOR BARRIER LOCATED AT BS 663.75 BETWEEN RBL 40 TO RBL 55 RH SIDE WHEEL WELL COMPARTMENT IAW B737-700 SRM 51-70-04-2R-10 REPAIR 10. SEE INDIVIDUAL SIGNS OFF BELOW.