What was found
CRACK FOUND ON LH HORIZONTAL STABILIZER LOWER IN-SPAR SKIN AT STATION 193.90 RIB; 17.5 INCHES FROM FRONT SPAR; INB SIDE OF RIB LENGTH APPROX= 0.980 INCHES 2025-298037<[01] TOOL USED ON STEP 3: EDDY CURRENT EQUIPMENT P/N: NORTEC 600D; S/N: 220273012; DUE DATE: 22-JAN-26.;[02] EQUIPMENT P/N PHASEC 3D; S/N 800YBRK; DUE DATE 16-JUL-25 WAS USED ON STEP 6;[03] PERFORMED REPAIR ON LT HORIZONTAL STABILIZER LOWER SKIN PANEL LOCATED AT STAB 193.90 RIB; 17.5 INCHES FROM FRONT SPAR I.A.W. B737-700 SRM: 55-10-01-2R-11. REPAIR 11. SEE INDIVIDUAL SIGNS OFF BELOW;[04] CERTIFIED ACTION 3; COMPLETED <BR>RII