What was found
REPAIR FUSELAGE BS986.5 UPPER FLOOR BEAM CAP CORROSION BLENDOUT EXTENDED ALLOWABLE DAMAGE 2025-309410<[01] TOOL USED ON STEP 1: ULTRASONIC THICKNESS GAGE; P/N:45MG; S/N:242232211; DUE DATE:14-NOV-25.;[02] REPAIRED FUSELAGE BS986.5 UPPER FLOOR BEAM CAP CORROSION BLEN DOUT EXTENDED ALLOWABLE DAMAGE M-21-153-00612 . SEE INDIVIDUAL SIGN-OFF BELOW;[03] REPAIRED FUSELAGE BS986.5 UPPER FLOOR BEAM CAP CORROSION BLEN DOUT EXTENDED ALLOWABLE DAMAGE M-21-153-00612 . SEE INDIVIDUAL SIGN-OFF BELOW