What was found
AAI MAIN CABIN FLOOR STRUCTURE SUPPORT HAS CRACK AT STA540 BL0 TO LBL24.75. 2025-309488<[01] REPLACED SUPPORT ASSY AND FASTENERS LOCATED ON MAIN CABIN FLOOR STRUCTURE FROM STA 540 BETWEEN BL 0 TO LBL 24.75 IAW B737-700 SRM 51-40-02 AND DWG #143A0060 SHEET 46 REV-.;[02] REPLACED SUPPORT ASSY AND FASTENERS LOCATED ON MAIN CABIN FLOOR STRUCTURE FROM STA 540 BETWEEN BL 0 TO LBL 24.75 IAW B737-700 SRM 51-40-02 AND DWG #143A0060 SHEET 46 REV-.