What was found
CRACK BRAKE PANEL FLOOR STRUCTURE LOCATED STA540 AND LBL1 AT PASSENGER CABIN. NOT FOUND ALLOWABLE DAMAGE FOR BRAKE PANEL ON SRM 53-30-51-1A-1 MEASURES ARE:L= 1.429 INCH. REPLACED BRAKE PANEL FLOOR STRUCTURE LOCATED STA540 AND BL 0 TO LBL 24.75 WL 208.1 AT PASSENGER CABIN IAW B737-700 SRM 51-10-02 ITEM 9 AND SRM 51-40-02 DWG 143A0060 SHEET 36 REV A.