What was found
L/H WING #3 FLAP FAIRING OUTBOARD SIDE HAS FOUR FASTENERS PULLED THROUGH FOR SEAL ATTACHMENT. THE LARGEST HOLE DIMENSION IS .25 IN. REPLACED SEAL 10-60754-20 & PERFORMED INTERIM REPAIR FOR ALTERNATIVE #1 OF THE #3 FLAP TRACK CANOE FAIRING ON THE OUTBOARD TRAILING EDGE PER SRM 57-53-70-02R-2. A DETAILED VISUAL INSPECTION IS DUE IN 500 FC OR MORE FREQUENTLY. TSR# 2025005839. AFTER REVIEW ENGINEERING CONCURS WITH THE SRM DEFERRAL FOR FAULT TTG8Q01353YL. REFERENCE TSR 2025005839. REPLACED SEAL 10-60754-20 & PERFORMED INTERIM REPAIR FOR ALTERNATIVE #1 OF THE #3 FLAP TRACK CANOE FAIRING ON THE OUTBOARD TRAILING EDGE PER SRM 57-53-70-02R-2.