What was found
CRACKED INTERCOSTAL AT FWD WET AREA BS390 RBL41 WL208. REMOVED AND REPLACED ANGLE AT FLOOR STRUCTURE RBL 41 WL 208 BETWEEN BS 380 TO BS 400 PER SRM 51-40-02 AND DWG 143A5400 REV -.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CRACKED INTERCOSTAL AT FWD WET AREA BS390 RBL41 WL208. REMOVED AND REPLACED ANGLE AT FLOOR STRUCTURE RBL 41 WL 208 BETWEEN BS 380 TO BS 400 PER SRM 51-40-02 AND DWG 143A5400 REV -.