What was found
CRACK INDICATION FOUND ON LT HORIZONTAL STABILIZER LOWER SKIN PANEL. LOCATED AT STAB STA 193.9 RIB AND 16.0 INCH. FROM FRONT SPAR. INBOARD SIDE OF RIB. CRACK LENGTH = 0.600 INCH. APPROX. 2025-335643 <[01] TOOL USED ON STEP 5 AND 6: ET EQUIPMENT; PN: NORTEC600D; SN:240494307; CAL DUE DATE:27-AUG-25; [02] PERFORMED PERMANENT REPAIR ON LH HORIZONTAL STABILIZER LOWER SKIN PANEL LOCATED AT STAB STA 193.9 RIB AND 16 INCH. FROM FRONT SPAR INBOARD SIDE OF RIB IAW B737-700 SRM 55-10-01-2R-11 REPAIR 11. SEE INDIVIDUAL SIGN OFF BELOW; [03] PERFORMED PERMANENT REPAIR ON LH HORIZONTAL STABILIZER LOWER SKIN PANEL LOCATED AT STAB STA 193.9 RIB AND 16 INCH. FROM FRONT SPAR INBOARD SIDE OF RIB IAW B737-700 SRM 55-10-01-2R-11 REPAIR 11. SEE INDIVIDUAL SIGN OFF BELOW.