What was found
CRACK ANGLE FLOOR STRUCTURE LOCATED STA 695 AND LBL 24.75 AT PASSENGER CABIN. REPLACED SUPPORT BRACKET AND NEW FASTENERS ON FLOOR STRUCTURE LOCATED STA 695 AND LBL 24.75 AT PASSENGER CABIN IAW SRM 51-40-02; SRM 51-10-02 ITEM 9 AND DWG 273A9110 SHEET 6 REV: A.