As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
CRACK ON BEAR STRAP SERVICE DOOR CUT OUT LOCATED STA294.5 AND BETWEEN STR 8R TO STR 9R AT FWD GALLEY AREA. PERFORMED PERMANENT REPAIR ON BEAR STRAP AREA LOCATED BETWEEN BS 277 TO BS 328 AND STR 5R TO STR 11R AT PASSENGER CABIN AREA IAW SRM 53-10-01-2R-6 REPAIR 6 AND EA: M-25-153-01539 REV A.