What was found
RH VAPOR BARRIER UPPER ATTACH ANGLE IS CRACKED AT BS 663 LBL 45 WL 167. REMOVED AND REPLACED NEW UPPER ATACH ANGLE BS 663 BETWEEN RBL 60 TO RBL 8 VAPOR BARRIER AREA PER SRM 51-40-02 AND DWG#111A1000 REV:- AND DWG# 111A0150 REV A.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
RH VAPOR BARRIER UPPER ATTACH ANGLE IS CRACKED AT BS 663 LBL 45 WL 167. REMOVED AND REPLACED NEW UPPER ATACH ANGLE BS 663 BETWEEN RBL 60 TO RBL 8 VAPOR BARRIER AREA PER SRM 51-40-02 AND DWG#111A1000 REV:- AND DWG# 111A0150 REV A.