What was found
CRACK ON ANGLE LOCATED DEFLECTION CONTROL RIB AREA AT LEVEL ORSS 261 AT RT WING. REPLACED WEB AND FASTENERS LOCATED DEFLECTION CONTROL RIB AREA AT LEVEL ORSS 261 AT RT WING IAW SRM 51-40-02, SRM 51-10-02, ITEM 9, AND DWG 115A2900, SHEET 1, REV E.