What was found
MULTIPLE SPOTS WITH CORROSION ON FCB DOOR CUTOUT SURROUND THRESHOLD BS440+14; BS460;460+9 RBL30;WL156. REMOVED AND REPLACED SUBTHRESHOLD WEB AT FCB; BETWEEN BS 440 TO BS 492 RBL 30 WL 156 IAW SRM 51-40-02 AND DWG 143A8330 REV -.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
MULTIPLE SPOTS WITH CORROSION ON FCB DOOR CUTOUT SURROUND THRESHOLD BS440+14; BS460;460+9 RBL30;WL156. REMOVED AND REPLACED SUBTHRESHOLD WEB AT FCB; BETWEEN BS 440 TO BS 492 RBL 30 WL 156 IAW SRM 51-40-02 AND DWG 143A8330 REV -.