What was found
CRACK FOUND BS 663 VAPOR BARRIER ATTACH ANGLE AT APPROXIMATELY LBL 9. REMOVED DAMAGED SECTION OF VAPOR BARRIER ATTACH ANGLE IAW SRM 57-10-10-2R-5. ACCOMPLISHED HFEC HOLE PROBE OF FASTENER HOLES COMMON TO FUEL TANK AND HFEC SURFACE INSP OF ATTACH ANGLE CUT LINE. NO DEFECTS NOTED, IAW NDT PART 6 51-00-00 PROC. 16 & 51-00-00 PROC. 23. FABRICATED REPAIR PARTS IAW SRM 57-10-10-2R-5, INSTALLED TANK FASTENERS IN THE REPAIR PARTS COMMON TO THE. VAPOR BARRIER ATTACH ANGLE IAW SRM 57-10-10-2R-5. C/W FASTENER INSTALL DOME SEALED FASTENERS INSIDE CENTER FUEL TANK COMMON TO VAPOR BARRIER ATTACH ANGLE IAW SOPM 20-50-19. INSTALLED FASTENERS IN VERTICAL LEG OF VAPOR BARRIER ATTACH ANGLE IAW SRM 57-10-10-2R-5. INSTALLED FASTENERS IN VERTICAL LEG OF VAPOR BARRIER ATTACH ANGLE IAW SRM 57-10-10-2R-5. CAP SEALED FASTENERS IN VERTICAL LEG OF VAPOR BARRIER ATTACH ANGLE IAW SRM 57-10-10-2R-5. CAP SEALED FASTENERS IN VERTICAL LEG OF VAPOR BARRIER ATTACH ANGLE IAW SRM 57-10-10-2R-5. REPAIRED BS 663 VAPOR BARRIER ATTACH ANGLE AT APPROXIMATELY LBL 9 IAW SRM 57-10-10.