What was found
CRACK INDICATIONS(2EA) ON STUB FRAME LOCATED BETWEEN BS 294.5 TO BS 296.5 AND BETWEEN S-8R TO S-9R AT FWD GALLEY DOOR AREA CRACK LENGTHS 1.00 IN. AND 1.187 IN. APROX.AT PASSENGER CABIN. REPLACED STUB FRAME LOCATED BETWEEN BS 294.5 TO BS296.5 AND BETWEEN S-7R TO S-10R AT FWD GALLEY DOOR AREA IAW SRM 51-10-02, SRM 51-40-02, DWG 141A8370, SHEET 9, REV D.