What was found
MULTIPLE SPOTS WITH CORROSION ON FCB DOOR CUTOUT SURROUND THRESHOLD BS440+7 TO BS480+4 RBL29;WL156. REMOVED AND REPLACED FCB SUBTHRESHOLD WEB BETWEEN BS 440 TO BS 492 RBL 29 WL 156 IAW SRM 51-40-02 AND DWG 143A8330 ID: 0030 REV: -.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
MULTIPLE SPOTS WITH CORROSION ON FCB DOOR CUTOUT SURROUND THRESHOLD BS440+7 TO BS480+4 RBL29;WL156. REMOVED AND REPLACED FCB SUBTHRESHOLD WEB BETWEEN BS 440 TO BS 492 RBL 29 WL 156 IAW SRM 51-40-02 AND DWG 143A8330 ID: 0030 REV: -.