What was found
CRACKED ON FLOOR SUPPORT BS 312 - 328, LBL45, WL208.1. REMOVED, LOCATED, DRILLED, AND INSTALLED THE FLOOR SUPPORT IAW SRM 51-40-02, SRM 51-40-05, AND DWG 141A5400, REV-.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CRACKED ON FLOOR SUPPORT BS 312 - 328, LBL45, WL208.1. REMOVED, LOCATED, DRILLED, AND INSTALLED THE FLOOR SUPPORT IAW SRM 51-40-02, SRM 51-40-05, AND DWG 141A5400, REV-.