What was found
CORROSION ON FLOOR STRUCTURE TEE ANGLE BETWEEN BS 270 TO BS 277 AND LBL 10 WL 208. REPLACED TEE ANGLE BS 270 TO BS 277, LBL 10, WL 208 IAW SRM 51-40-02 AND DWG 141A5600 SHEET 1 AND 2; REV N.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CORROSION ON FLOOR STRUCTURE TEE ANGLE BETWEEN BS 270 TO BS 277 AND LBL 10 WL 208. REPLACED TEE ANGLE BS 270 TO BS 277, LBL 10, WL 208 IAW SRM 51-40-02 AND DWG 141A5600 SHEET 1 AND 2; REV N.