What was found
CRACKED FLOOR SUPPORT BETWEEN BS 312 - 328, LBL 46 IN THE FWD GALLEY AND LAV. REPLACED FLOOR SUPPORT IAW SRM 51-10-02-0G-0, SRM 51-40-02-0G-0, AND DWG 141A5400, SHEET 26, REV -.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CRACKED FLOOR SUPPORT BETWEEN BS 312 - 328, LBL 46 IN THE FWD GALLEY AND LAV. REPLACED FLOOR SUPPORT IAW SRM 51-10-02-0G-0, SRM 51-40-02-0G-0, AND DWG 141A5400, SHEET 26, REV -.